A comparison of two methods of determining thermal properties of footwear

Författare

  • Kalev Kuklane
  • Ingvar Holmér
  • Ralemma Afanasieva

Summary, in English

The present European Standard for footwear testing (EN 344) classifies footwear thermally by a temperature drop inside the footwear during 30 minutes at defined conditions. Today, other methods for footwear thermal testing are also available. The aim of this study was to compare EN 344 with thermal foot method. Six boots were tested according to both methods. Additional tests with modified standard tests were also carried out. The methods ranked the footwear in a similar way. However, the test according to EN 344 is a pass/fail test, while data that is gained from thermal foot method does give more information and allows further use in research and product development. The change of present standard method was suggested.

Publiceringsår

1999

Språk

Engelska

Sidor

477-484

Publikation/Tidskrift/Serie

International Journal of Occupational Safety and Ergonomics

Volym

5

Issue

4

Dokumenttyp

Artikel i tidskrift

Förlag

Taylor & Francis

Ämne

  • Production Engineering, Human Work Science and Ergonomics

Nyckelord

  • thermal insulation
  • thermal foot model
  • footwear
  • standard

Status

Published

Forskningsgrupp

  • Thermal Environment Laboratory

ISBN/ISSN/Övrigt

  • ISSN: 2376-9130