Interaction between hydrogen peroxide and titanium: a possible role in the biocompatibility of titanium

Författare

Summary, in English

Hydroxyl radicals formed from hydrogen peroxide during an inflammatory response are potent agents for cellular deterioration. The behaviour of implanted material in terms of its ability to sustain or stop free radical formation may be therefore very important. In vitro studies of titanium which is known to be biocompatible and osseointegrates into human bone were carried out. In our model studies, the production of free radicals from H2O2 at Ti and TiO2 surfaces was measured by spin trapping techniques. Our findings suggest that there is no sustained hydroxyl radical production at a titanium (oxide) surface. We propose that this is due to the quenching of the Fenton reaction through both trapping and oxidation of superoxide radicals in a TiOOH adduct.

Publiceringsår

1989

Språk

Engelska

Sidor

118-120

Publikation/Tidskrift/Serie

Biomaterials

Volym

10

Issue

2

Dokumenttyp

Artikel i tidskrift

Förlag

Elsevier

Ämne

  • Bioengineering Equipment

Nyckelord

  • Titanium
  • hydrogen peroxide
  • oxygen radicals
  • biocompatibility

Status

Published

ISBN/ISSN/Övrigt