Webbläsaren som du använder stöds inte av denna webbplats. Alla versioner av Internet Explorer stöds inte längre, av oss eller Microsoft (läs mer här: * https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Var god och använd en modern webbläsare för att ta del av denna webbplats, som t.ex. nyaste versioner av Edge, Chrome, Firefox eller Safari osv.

Method for ultrastructural studies of the intact tissue-metal interface

Författare

Summary, in English

Samples were prepared for ultrastructural studies of the intact interface between metallic implants and tissue by transmission electron microscopy. The method is based on plastic embedding of implant and tissue and subsequent removal of the bulk metal by electrochemical dissolution (electropolishing), to facilitate preparation of ultrathin sections for transmission electron microscopy. Surface sensitive spectroscopy (Auger electron microscopy and X-ray photoemission spectroscopy) and transmission electron microscopy EDX results show that the method produces samples with an intact interface, containing the implant surface oxide and the adjacent tissue. Examples of application of the method on titanium, zirconium and aluminium implants in soft tissue are given.

Publiceringsår

1990

Språk

Engelska

Sidor

596-601

Publikation/Tidskrift/Serie

Biomaterials

Volym

11

Issue

8

Dokumenttyp

Artikel i tidskrift

Förlag

Elsevier

Ämne

  • Bioengineering Equipment

Nyckelord

  • Titanium
  • cell-material interface
  • ultrastructure

Status

Published

ISBN/ISSN/Övrigt

  • ISSN: 1878-5905