Webbläsaren som du använder stöds inte av denna webbplats. Alla versioner av Internet Explorer stöds inte längre, av oss eller Microsoft (läs mer här: * https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Var god och använd en modern webbläsare för att ta del av denna webbplats, som t.ex. nyaste versioner av Edge, Chrome, Firefox eller Safari osv.

Biological monitoring of N-methyl-2-pyrrolidone using 5-hydroxy-N-methyl-2-pyrrolidone in plasma and urine as the biomarker

Författare

  • Bengt Åkesson
  • Bo A Jönsson

Summary, in English

OBJECTIVES: The aims were to study the toxicokinetics of 5-hydroxy-N-methyl-2-pyrrolidone (5-HNMP) in blood and urine after exposure to N-methyl-2-pyrrolidone (NMP) and to study the suitability of 5-HNMP as a biomarker for assessing NMP exposure. METHODS: Six male volunteers were exposed for 8 hours to NMP concentrations of 0, 10, 25, and 50 mg/m3. Blood and urine were sampled before, during, and up to 40 hours after exposure. Aliquots of urine and plasma were purified, derivatized, and analyzed for 5-HNMP on a gas chromatograph/mass spectrometer in the electron impact mode. RESULTS: The mean plasma concentration [P-(5-HNMP)] after 8-hour NMP exposure to 10, 25, and 50 mg/m3 was 8.0, 19.6, and 44.4 micromol/l, respectively. The mean urinary concentration [U-(5-HNMP)] for the 2 last hours of exposure was 17.7, 57.3, and 117.3 mmol/mol creatinine, respectively. The maximal P-(5-HNMP)and U-(5-HNMP) concentrations occurred 1 hour and 0-2 hours, respectively, after the exposure. The half-times of P-(5-HNMP) and U-(5-HNMP) were 6.3 and 7.3 hours, respectively. The 5-HNMP urinary concentrations were 58% of the calculated retained dose. There was a close correlation (r) between P-(5-HNMP) (r=0.98) and U-(5-HNMP) (r=0.97) with NMP exposure. CONCLUSIONS: 5-HNMP is an excellent biomarker for assessing exposure to NMP. Its plasma and urinary half-times (6-7 hours), the minimal risk for contamination during sampling in occupational settings, and the close correlation of P-(5-HNMP) and U-(5-HNMP) with NMP exposure makes 5-HNMP suitable for monitoring exposure to NMP. 5-HNMP in plasma is recommended.

Publiceringsår

2000

Språk

Engelska

Sidor

213-218

Publikation/Tidskrift/Serie

Scandinavian Journal of Work, Environment and Health

Volym

26

Issue

3

Dokumenttyp

Artikel i tidskrift

Förlag

Finnish Institute of Occupational Health

Ämne

  • Environmental Health and Occupational Health

Nyckelord

  • graffiti remover
  • paint stripper
  • reproductive toxicity
  • skin uptake
  • solvent

Status

Published

ISBN/ISSN/Övrigt

  • ISSN: 0355-3140