Meny

Javascript is not activated in your browser. This website needs javascript activated to work properly.
Du är här

Monitoring of enzymatic hydrolysis of starch by microdialysis sampling coupled on-line to anion exchange chromatography and integrated pulsed electrochemical detection using post-column switching

Författare:
Publiceringsår: 1997
Språk: Engelska
Sidor: 546-554
Publikation/Tidskrift/Serie: Biotechnology and bioengineering
Volym: 56
Nummer: 5
Dokumenttyp: Artikel
Förlag: Wiley Periodicals, Inc.

Sammanfattning

A quantitative evaluation of the hydrolysis of wheat starch using Termamyl, a thermostable alpha-amylase (endo-1,4-alpha-d-glucan, glucanohydrolase; EC 3.2.1.78), is reported. Data from the monitoring of the hydrolysis of wheat starch indicated that, after 1 h, glucose and maltooligosaccharides up to DP 7 were the main hydrolysis products and thus enabled optimization of a liquefication step during the production of L-lactic acid. The monitoring system used, both in the on- and off-line mode, was based on continuous flow microdialysis sampling (CFMS) coupled to anion exchange chromatography and integrated pulsed electrochemical detection (IPED). A microdialysis probe equipped with a 5-mm polysulfone (SPS 4005) membrane, with a molecular-weight cut-off of 5 kDa, was used to sample the hydrolysis products of native wheat starch at 90 degrees C. Characteristic fingerprint separations were achieved by anion exchange chromatography after enzymatic hydrolysis. Post-column switching improved the detection and, consequently, also quantification of the hydrolysates as fouling of the electrode could be reduced. Maltooligosaccharide standards were used for quantification and to verify the elution of the hydrolysates by spiking the off-line samples. (c) 1997 John Wiley & Sons, Inc. Biotechnol Bioeng 56: 546-554, 1997.

Disputation

Nyckelord

  • Chemistry

Övriga

Published
Yes
  • ISSN: 0006-3592

Box 117, 221 00 LUND
Telefon 046-222 00 00 (växel)
Telefax 046-222 47 20
lu [at] lu [dot] se

Fakturaadress: Box 188, 221 00 LUND
Organisationsnummer: 202100-3211
Om webbplatsen