Development of a picosecond lidar system for large-scale combustion diagnostics.

Författare

Summary, in English

In the present work, a picosecond lidar system aiming at single-ended combustion diagnostics in full-scale combustion devices with limited optical access, such as power plants, is described. The highest overall range resolution of the system was found to be <0.5 cm. A demonstration has been made in a nonsooty and sooty Bunsen burner flame. A well-characterized ethylene flame on a McKenna burner was evaluated for different equivalence ratios using Rayleigh thermometry. The results indicate both that picosecond lidar might be applicable for single-shot Rayleigh thermometry, even two-dimensional, and that there is a possibility to qualitatively map soot occurrence. Furthermore, differential absorption lidar has been investigated in acetone vapor jets for fuel visualization purposes.

Publiceringsår

2009

Språk

Engelska

Sidor

65-72

Publikation/Tidskrift/Serie

Applied Optics

Volym

48

Issue

4

Dokumenttyp

Artikel i tidskrift

Förlag

Optical Society of America

Ämne

  • Atom and Molecular Physics and Optics

Status

Published

ISBN/ISSN/Övrigt

  • ISSN: 2155-3165