Du är här

Corrector-based magnet alignment procedure

Publiceringsår: 2008
Språk: Engelska
Sidor: 170-177
Publikation/Tidskrift/Serie: Nuclear Instruments & Methods in Physics Research Section a-Accelerators Spectrometers Detectors and Associated Equipment
Volym: 597
Nummer: 2-3
Dokumenttyp: Artikel
Förlag: Elsevier Science

Sammanfattning

A method of realigning the quadrupole magnets in storage rings to achieve minimum dipole corrector strengths is described. The corrector strengths after realignment are mainly determined by Beam Position Monitor offsets relative to the quadrupole magnets they have been calibrated against and the extent to which magnet dipole errors stay constant during the realignment. The accuracy to which quadrupole misalignments can be determined is mainly limited by dipole errors not originating from quadrupole displacements and the accuracy to which BPM offsets can be determined. After realigning a ring by the described method, any subsequent realignment with the aim to compensate for long-term magnet movements can be performed with greater accuracy. The method was applied at the MAX III storage ring and the magnet positions were then measured in the conventional way with a laser tracker. The difference between the two methods is discussed. Finally, the realignment result was compared with simulated results for two different MAX III test cases. (C) 2008 Elsevier B.V. All rights reserved.

Disputation

Nyckelord

  • Physics and Astronomy
  • Accelerator
  • Alignment
  • Corrector magnet
  • Positioning

Övrigt

Published
Yes
  • ISSN: 0168-9002

Box 117, 221 00 LUND
Telefon 046-222 00 00 (växel)
Telefax 046-222 47 20
lu [at] lu [dot] se

Fakturaadress: Box 188, 221 00 LUND
Organisationsnummer: 202100-3211
Om webbplatsen

LERU logo U21 logo