Webbläsaren som du använder stöds inte av denna webbplats. Alla versioner av Internet Explorer stöds inte längre, av oss eller Microsoft (läs mer här: * https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Var god och använd en modern webbläsare för att ta del av denna webbplats, som t.ex. nyaste versioner av Edge, Chrome, Firefox eller Safari osv.

Spatiotemporal evolution of CO2 concentration, temperature, and wind field during stable nights at the Norunda forest site

Författare

Summary, in English

Unusually high CO2 concentrations were frequently observed during stable nights in late summer 2006 at the CarboEurope-Integrated Project (CEIP) forest site in Norunda, Sweden. Mean CO2 concentrations in the layer below the height of the eddy-covariance measurement system at 30 m reached up to 500 mu mol mol(-1) and large vertical and horizontal gradients occurred, leading to very large advective fluxes with a high variability in size and direction. CO2 accumulation was found to build up in the second part of the night, when the stratification in the canopy sub-layer turned from stable to neutral. Largest vertical gradients of temperature and CO2 were shifted from close to the ground early in the night to the crown space of the forest late at night, decoupling the canopy sub-layer from the surface roughness layer. At the top of the canopy at 25 m CO2 concentrations up to 480 mu mol mol(-1) were observed at all four tower locations of the 3D cube setup and concentrations were still high (>400 mu mol mol(-1)) at the 100 m level of the Central tower. The vertical profiles of horizontal advective fluxes during the nights under investigation were similar and showed largest negative horizontal advection (equivalent to an additional CO2-sink) to occur in the crown space of the forest, and not, as usually expected, close to the ground. The magnitude of these fluxes was sometimes larger than 50 mu mol m(-2) s(-1)and they were caused by the large horizontal CO2 concentration gradients with maximum values of up to 1 mu mol mol(-1) m(-1). As a result of these high within canopy CO2 concentrations, the vertical advection also became large with frequent changes of direction according to the sign of the mean vertical wind component, which showed very small values scattering around zero. Inaccuracy of the sonic anemometer at such low wind velocities is the reason for uncertainty in vertical advection, whereas for horizontal advection, instrument errors were small compared to the fluxes. The advective fluxes during these nights were unusually high and it is not clear what they represent in relation to the biotic fluxes. Advection is most likely a scale overlapping process. With a control volume of about 100 m x 100 m x 30 m and the applied spatial resolution of the sensors, we obviously miss relevant information from processes in the mesoscale as well as in the turbulent scale. (C) 2009 Elsevier B.V. All rights reserved.

Publiceringsår

2010

Språk

Engelska

Sidor

692-701

Publikation/Tidskrift/Serie

Agricultural and Forest Meteorology

Volym

150

Issue

5

Dokumenttyp

Artikel i tidskrift

Förlag

Elsevier

Ämne

  • Physical Geography

Nyckelord

  • Gradients
  • ADVEX
  • Carbon balance
  • Net ecosystem exchange
  • Forest ecosystems
  • Advection

Status

Published

ISBN/ISSN/Övrigt

  • ISSN: 1873-2240