Comparison of geoelectrical imaging and tunnel documentation at the Hallandsas Tunnel, Sweden

Författare

Summary, in English

For construction in rock a thorough pre-investigation is important in order to avoid unforeseen conditions which may delay the work. It is crucial to remember the results from this investigation in the further work, and use the experience from the construction to update the geological prognosis and reduce the uncertainties. Different geophysical methods have proved valuable tools in such investigations. In this work the electrical imaging is evaluated with regards to the method's applicability. The evaluation is done qualitatively by comparing the electrical imaging with tunnel documentation from a tunnel in Southern Sweden. By evaluating the result continuously when making the tunnel a more detailed geological prognosis can be compiled and used in the continued work with the tunnel. The parameters used for the comparison are lithology, Q, RQD, weathering and water leakage. The result was that virtually every change in electrical resistivity image coincides with a change in rock conditions. The general trend was that high resistivity corresponded with good quality gneiss whereas low resistivity corresponds to poor quality rock e.g., high weathering, low RQD, low Q and/or several lithological contacts. The intermediate resistivity is often amphibolites or rock with water bearing fractures. The results were supported by in-situ resistivity measurements inside the tunnel and resistivity logging in a core drilling. Geoelectrical imaging proved to give valuable information for a detailed geological model, which could be compiled for a section where the tunnel had not yet been drilled as a help for planning of the continued tunnel work. As is the case other geophysical methods it is clear that for the interpretation of data a priori information about the geological setting is necessary. (C) 2009 Elsevier B.V. All rights reserved.

Avdelning/ar

Publiceringsår

2009

Språk

Engelska

Sidor

118-129

Publikation/Tidskrift/Serie

Engineering Geology

Volym

107

Issue

3-4

Dokumenttyp

Artikel i tidskrift

Förlag

Elsevier

Ämne

  • Geotechnical Engineering

Nyckelord

  • Weathering
  • RQD
  • Q
  • Lithology
  • Geoelectrical imaging
  • Comparison
  • Tunnel documentation
  • Resistivity
  • Water leakage
  • Dynamic prognosis