Webbläsaren som du använder stöds inte av denna webbplats. Alla versioner av Internet Explorer stöds inte längre, av oss eller Microsoft (läs mer här: * https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Var god och använd en modern webbläsare för att ta del av denna webbplats, som t.ex. nyaste versioner av Edge, Chrome, Firefox eller Safari osv.

Moderate varus/valgus malalignment after total knee arthroplasty has little effect on knee function or muscle strength 91 patients assessed after 1 year

Författare

  • Justinas Stucinskas
  • Otto Robertsson
  • Aurimas Sirka
  • Aleksej Lebedev
  • Hans Wingstrand
  • Sarunas Tarasevicius

Summary, in English

Background and purpose - Postoperative muscle strength and component alignment are important factors affecting functional results after total knee arthroplasty (TKA). We are not aware of any studies that have investigated the relationship between them. We therefore investigated whether coronal malalignment of the mechanical axis and/or of individual implant components would affect knee muscle strength and function 1 year after TKA surgery. Patients and methods - We included 120 consecutive osteoarthritis (OA) patients admitted for TKA. Preoperative active range of motion (ROM) of the knee, patient age, sex, and BMI were recorded and the Knee Society score (KSS) and knee joint extensor/flexor muscle strength were assessed. At 1-year follow-up, the mechanical and coronal component alignment was measured from a postoperative long standing radiograph, and ROM, KSS, and muscle strength measurements were taken in 91 patients. Functional outcome and muscle strength measurements were compared between normally aligned and malaligned TKA groups. Results - 29 of 91 TKAs were malaligned, i.e. they deviated more than 3 degrees from the neutral mechanical axis. 18 femoral components and 15 tibial components were malaligned. Before surgery, the malaligned and normally aligned groups were similar regarding sex distribution, BMI, ROM, KSS, and muscle strength. At the 1-year follow-up, the differences between the groups regarding knee joint function and muscle strength were small, not statistically significant, and barely clinically relevant. Interpretation - Moderate varus/valgus malalignment of the mechanical axis or of individual components has no relevant clinical effect on function or muscle strength 1 year after TKA surgery.

Publiceringsår

2015

Språk

Engelska

Sidor

728-733

Publikation/Tidskrift/Serie

Acta Orthopaedica

Volym

86

Issue

6

Dokumenttyp

Artikel i tidskrift

Förlag

Taylor & Francis

Ämne

  • Orthopedics

Status

Published

ISBN/ISSN/Övrigt

  • ISSN: 1745-3682