A numerical and experimental study of Polycyclic Aromatic Hydrocarbons in a laminar diffusion flame

Författare

  • L. M. Verhoeven
  • M. H. de Andrade Oliveira
  • Andreas Lantz
  • Bo Li
  • Zhongshan Li
  • C. C. M. Luijten
  • J. A. van Oijen
  • Marcus Aldén
  • L. P. H. de Goey

Summary, in English

During the process of biomass gasification tars are formed which exit the gasifier in vapor phase. Tar condensation creates problems like fouling and plugging of after-treatment, conversion and end-use equipment. Gasification tars consist mainly of Polycyclic Aromatic Hydrocarbons (PAHs). Former research has shown the possibilities and difficulties of tar conversion by partial combustion. Basic studies to investigate the oxidation of tars in non-premixed combustion processes are expected to give more insight in this problem. In this paper the ability of the flamelet-generated manifold (FGM) approach to numerically model multi-dimensional, laminar, non-premixed flames with the inclusion of PAH chemistry is investigated. Modeling detailed PAH chemistry requires the employment of large reaction mechanisms which lead to expensive numerical calculations. The application of a reduction technique like FGM leads to a considerable decrease (up to two orders) in the required computation time. A 1D numerical validation shows that the improvements achieved by implementing a varying Lewis number for the progress variable Y are significant for PAH species with a large Lewis number, such as C10H8. Considerable improvements are found near the flame front and on the fuel side of the flame. A comparison has been made of FGM results with qualitative Planar Laser Induced Fluorescence (PLIF) measurements. A laminar CH4/N-2-air co-flow flame has been doped with two dopants, benzene and toluene, at three different concentrations. A set of filters was used in order to qualitatively distinguish the small (1-2 rings) and large (3 or more rings) aromatic species. The results show that the model is able to capture the major flame characteristics typical for PAH formation in multi-dimensional laminar non-premixed flames. (C) 2012 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

Publiceringsår

2013

Språk

Engelska

Sidor

1819-1826

Publikation/Tidskrift/Serie

Proceedings of the Combustion Institute

Volym

34

Dokumenttyp

Artikel i tidskrift

Förlag

Elsevier

Ämne

  • Atom and Molecular Physics and Optics

Nyckelord

  • Tar
  • Flamelet Generated Manifolds
  • Laminar non-premixed flames
  • Planar
  • Laser Induced Fluorescence
  • PAH chemistry

Status

Published

ISBN/ISSN/Övrigt

  • ISSN: 1540-7489