A method to determine the critical moisture level for unsaturated transport of ions

Författare

Summary, in English

This study describes a method to obtain a certain humidity level by a certain drying treatment. This treatment was applied on cement based materials in order to identify the critical moisture level above which ion transport can occur. The drying is performed in two steps, first in one direction to reach a certain moisture level and then in the opposite direction to identify if ions can move at this lower level. This treatment gives an opportunity to determine ion transport at a well defined humidity, both in terms of moisture content and relative humidity. Ion transport was indicated by analyzing the potassium distribution on slices of mortar by SEM–EDS.

Publiceringsår

2015

Språk

Engelska

Sidor

53-65

Publikation/Tidskrift/Serie

Materials and Structures

Volym

48

Issue

1-2

Dokumenttyp

Artikel i tidskrift

Förlag

Springer

Ämne

  • Materials Engineering

Nyckelord

  • Humidity
  • Drying
  • Physical properties
  • Transport properties
  • Mortar