Webbläsaren som du använder stöds inte av denna webbplats. Alla versioner av Internet Explorer stöds inte längre, av oss eller Microsoft (läs mer här: * https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Var god och använd en modern webbläsare för att ta del av denna webbplats, som t.ex. nyaste versioner av Edge, Chrome, Firefox eller Safari osv.

Protection against cold in prehospital care — thermal insulation properties of blankets and rescue bags in different wind conditions

Författare

  • Otto Henriksson
  • Peter Lundgren
  • Kalev Kuklane
  • Ingvar Holmér
  • Ulf Bjornstig

Summary, in English

Introduction: In a cold,wet, or windy environment, cold exposure can be considerable for an injured or ill person. The subsequent autonomous stress

response initially will increase circulatory and respiratory demands, and as body core temperature declines, the patient’s condition might deteriorate. Therefore, the application of adequate insulation to reduce cold exposure and prevent body core cooling is an important part of prehospital primary care, but recommendations for what should be used in the field mostly depend on tradition and experience, not on scientific evidence.

Objective: The objective of this study was to evaluate the thermal insulation properties in different wind conditions of 12 different blankets and rescue bags commonly used by prehospital rescue and ambulance services.

Methods: The thermal manikin and the selected insulation ensembles were setup inside a climatic chamber in accordance to the modified European Standard for assessing requirements of sleeping bags. Fans were adjusted to provide low (< 0.5 m/s), moderate (2–3 m/s) and high (8–9 m/s) wind conditions.

During steady state thermal transfer, the total resultant insulation value, Itr (m2 °C/Wclo; where °C = degrees Celcius, and W = watts), was calculated from ambient air temperature (°C), manikin surface temperature (°C), and heat flux (W/m2).

Results: In the low wind condition, thermal insulation of the evaluated ensembles correlated to thickness of the ensembles, ranging from 2.0 to 6.0 clo (1 clo = 0.155 m2 °C/W), except for the reflective metallic foil blankets that had higher values than expected. In moderate and high wind conditions, thermal insulation was best preserved for ensembles that were windproof and resistant to the compressive effect of the wind, with insulation reductions down to about 60–80% of the original insulation capacity, whereas wind permeable and/or lighter materials were reduced down to about 30–50% of original insulation capacity.

Conclusions: The evaluated insulation ensembles might all be used for prehospital protection against cold, either as single blankets or in multiple layer combinations, depending on ambient temperatures. However, with extended outdoor, on-scene durations, such as during prolonged extrications or in multiple casualty situations, the results of this study emphasize the importance of using a windproof and compression resistant outer ensemble to maintain adequate insulation capacity.

Publiceringsår

2009

Språk

Engelska

Sidor

408-415

Publikation/Tidskrift/Serie

Journal of Prehospital and Disaster Medicine

Volym

24

Issue

5

Dokumenttyp

Artikel i tidskrift

Förlag

World Association for Disaster and Emergency Medicine

Ämne

  • Production Engineering, Human Work Science and Ergonomics

Nyckelord

  • body temperature regulation
  • cold
  • emergency medical services
  • hypothermia
  • thermal insulation
  • thermal manikin
  • wind

Status

Published

Forskningsgrupp

  • Thermal Environment Laboratory