Around-the-Clock, Rapid Diagnosis of Influenza by Means of Membrane Chromatography Antigen Testing Confirmed by Polymerase Chain Reaction *

Författare

Summary, in English

One rapid membrane chromatography test and 2 immunofluorescence tests were compared with polymerase chain reaction as tools for the diagnosis of influenza in 277 patients treated in an emergency department. The sensitivity on days 1-3 of symptoms was 71% for the rapid membrane chromatography test, 70% for the first immunofluorescence test, and 79% for the second immunofluorescence test. Rapid tests are useful for round-the-clock identification of influenza, with follow-up polymerase chain reaction used for confirmation.

Avdelning/ar

Publiceringsår

2008

Språk

Engelska

Sidor

177-179

Publikation/Tidskrift/Serie

Infection Control & Hospital Epidemiology

Volym

29

Issue

2

Dokumenttyp

Artikel i tidskrift

Förlag

University of Chicago Press

Ämne

  • Infectious Medicine

Status

Published

Forskningsgrupp

  • Infectious Diseases Research Unit
  • Clinical Microbiology, Malmö

ISBN/ISSN/Övrigt

  • ISSN: 0899-823X