A small-scale matric potential sensor based on time domain reflectometry
Författare
Summary, in English
Measurements of soil matric potential (Psi) are needed in many soil science applications. In the present study, a small matric potential sensor having a length of 30 mm and a diameter of 9.6 mm was developed. The sensor consists of two coils made of lacquer-coated copper wires embedded in gypsum. The dielectric constant of the gypsum (K-gypsum) was measured with time domain reflectometry (TDR). The gypsum probes were tested in a sandy loam soil using a pressure extractor to obtain the relationship between K-gypsum and Psi, allowing inference of the soil Psi in equilibrium with the sensor. It was shown that the gypsum probe could give Psi estimates with a root mean square error (RMSE) of around 50 kPa in the range of -20 to -1500 kPa. Most of the sensitivity of the sensor was in the -50- to -1000-kPa range.
Publiceringsår
2006
Språk
Engelska
Sidor
533-536
Publikation/Tidskrift/Serie
Soil Science Society of America Journal
Volym
70
Issue
2
Fulltext
- Available as PDF - 151 kB
- Download statistics
Dokumenttyp
Artikel i tidskrift
Förlag
Soil Science Society of Americ
Ämne
- Water Engineering
- Geotechnical Engineering
Status
Published
ISBN/ISSN/Övrigt
- ISSN: 0361-5995