Webbläsaren som du använder stöds inte av denna webbplats. Alla versioner av Internet Explorer stöds inte längre, av oss eller Microsoft (läs mer här: * https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Var god och använd en modern webbläsare för att ta del av denna webbplats, som t.ex. nyaste versioner av Edge, Chrome, Firefox eller Safari osv.

Fire Safety Risk Analysis of a Hotel

Författare

Summary, in English

The first order second moment (FOSM) method is used for deriving a risk measure for safety of people in hotels. The measure is the reliability index ß. The safety is expressed as the evacuation time margin which is the difference between the available time before untenable conditions occur and the evacuation time. These times are subjected to uncertainty. The reliability index is used to determine the probability that the escape time margin will be negative. The influences on the reliability index from different escape alarm systems and smoke detection systems are investigated. Two risk definitions are described. Risk is defined for the guest in the fire room and for the other guests on the floor of the fire. Only fires in a guest room are considered. A traditional risk analysis is also performed to determine the influence of the floor plan size and the type of escape alarm on the safety level.

Publiceringsår

1997

Språk

Engelska

Publikation/Tidskrift/Serie

LUTVDG/TVBB--3091--SE

Dokumenttyp

Rapport

Förlag

Department of Fire Safety Engineering and Systems Safety, Lund University

Ämne

  • Other Civil Engineering
  • Building Technologies

Nyckelord

  • Fire
  • Risk analysis
  • Hotel
  • Reliability index
  • Evacuation
  • FOSM method

Status

Published

Report number

3091

ISBN/ISSN/Övrigt

  • ISSN: 1102-8246