High-frequency components in ECG analysed in guinea-pig Langendorf preparations

Författare

Summary, in English

High-frequency components in ECG during global ischaemia were studied in isolated guinea-pig hearts perfused ad modum Langendorf. Electrocardiograph recordings were carried out from the epicardial surface both in normo- and low-flow perfusion. After bandpass filtering (5-500 Hz), signal-averaging, was undertaken. The high-frequency components either increased or decreased after low-flow perfusion was instituted. Root-mean-square voltage (RMS) of the depolarization signal correlated poorly with the signal amplitude, but highly with the first and second derivative, i.e. the velocity and the acceleration of the signal. It is concluded that high-frequency components are not pathological phenomena per se, but reflect the shape of the original electrocardiographic signal.

Publiceringsår

2001

Språk

Engelska

Sidor

576-583

Publikation/Tidskrift/Serie

Clinical Physiology

Volym

21

Issue

5

Dokumenttyp

Artikel i tidskrift

Förlag

John Wiley & Sons Inc.

Ämne

  • Cardiac and Cardiovascular Systems

Status

Published

ISBN/ISSN/Övrigt

  • ISSN: 1365-2281