PIV and CFD measurements of internal velocity in a forming drop in a liquid-liquid system
Författare
Summary, in English
A PIV method has been used to determine the internal motion in an oil drop during formation and to validate a numerical simulation of the drop formation process. The PIV system included a microscope attached to the camera, which gave a focal depth of 50 µm and a possibility to measure the velocity in the centre cross section of the drop. Oil was forced through a capillary with a diameter of 200 µm into a channel with a cross-flowing continuous phase that induced a shear at the interface of the forming drop, which resulted in a rotational motion inside the drop. The angular velocity in the drop reached a maximum after 1/4 of the drop formation time and approached a steady state before drop detachment when a neck was formed above the capillary opening. The velocity of oil out of the capillary was also investigated. A clear dependence on the pressure inside the forming drop was obtained.
Avdelning/ar
- Department of Food Technology, Engineering and Nutrition
Publiceringsår
2007
Språk
Engelska
Sidor
1-10
Publikation/Tidskrift/Serie
7th International Symposium on Particle Image Velocimetry
Fulltext
- Available as PDF - 214 kB
- Download statistics
Dokumenttyp
Konferensbidrag
Ämne
- Food Engineering
Conference name
7th International Symposium on Particle Image Velocimetry
Conference date
2007-09-11 - 2007-09-14
Status
Published