Meny

Javascript verkar inte påslaget? - Vissa delar av Lunds universitets webbplats fungerar inte optimalt utan javascript, kontrollera din webbläsares inställningar.
Du är här

Iron loss calculation in a claw-pole structure

Författare:
Publiceringsår: 2004
Språk: Engelska
Sidor: 5
Dokumenttyp: Konferensbidrag

Sammanfattning

The total core loss in a claw-pole structure has been calculated on the basis of the variation of the magnetic loading over the magnetization cycle in different parts of the machine. This variation has been estimated from a lumped parameter permeance network and 3D finite element simulations, studying the flux density waveform and loci in their elements. The results from the simulations are compared with the loss measurements in a single-phase claw-pole motor equipped with an outer permanent-magnet rotor. Results show that the static and dynamic losses are underestimated by 35% and up to 60% at 100Hz respectively. Finally, the results from an optimization process are presented, where the torque performance is evaluated as a function of the pole number and dimensions of the machine

Disputation

Nyckelord

  • Technology and Engineering
  • soft magnetic composite (SMC) materials
  • optimization
  • lumped parameter permeance network
  • core losses
  • 3D finite element field computation
  • claw-pole machines

Övriga

Nordic Workshop on Power and Industrial Electronics, NORPIE'04
14-16 June, 2004
Trondheim, Norway
Published
Yes

Box 117, 221 00 LUND
Telefon 046-222 00 00 (växel)
Telefax 046-222 47 20
lu [at] lu [dot] se

Fakturaadress: Box 188, 221 00 LUND
Organisationsnummer: 202100-3211
Om webbplatsen