Webbläsaren som du använder stöds inte av denna webbplats. Alla versioner av Internet Explorer stöds inte längre, av oss eller Microsoft (läs mer här: * https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Var god och använd en modern webbläsare för att ta del av denna webbplats, som t.ex. nyaste versioner av Edge, Chrome, Firefox eller Safari osv.

Intercomparison of C-14 Analysis of Carbonaceous Aerosols: Exercise 2009

Författare

  • S. Szidat
  • G. Bench
  • V. Bernardoni
  • G. Calzolai
  • C. I. Czimczik
  • L. Derendorp
  • U. Dusek
  • K. Elder
  • M. E. Fedi
  • Johan Genberg
  • O. Gustafsson
  • E. Kirillova
  • M. Kondo
  • A. P. McNichol
  • Nolwenn Perron
  • G. M. Santos
  • Kristina Stenström
  • Erik Swietlicki
  • M. Uchida
  • R. Vecchi
  • L. Wacker
  • Y. L. Zhang
  • A. S. H. Prevot

Summary, in English

Radiocarbon analysis of the carbonaceous aerosol allows an apportionment of fossil and non-fossil sources of airborne particulate matter (PM). A chemical separation of total carbon (TC) into its subfractions organic carbon (OC) and elemental carbon (EC) refines this powerful technique, as OC and EC originate from different sources and undergo different processes in the atmosphere. Although C-14 analysis of TC, EC, and OC has recently gained increasing attention, interlaboratory quality assurance measures have largely been missing, especially for the isolation of EC and OC. In this work, we present results from an intercomparison of 9 laboratories for C-14 analysis of carbonaceous aerosol samples on quartz fiber filters. Two ambient PM samples and 1 reference material (RM 8785) were provided with representative filter blanks. All laboratories performed C-14 determinations of TC and a subset of isolated EC and OC for isotopic measurement. In general, C-14 measurements of TC and OC agreed acceptably well between the laboratories, i.e. for TC within 0.015-0.025 (FC)-C-14 for the ambient filters and within 0.041 (FC)-C-14 for RM 8785. Due to inhomogeneous filter loading, RM 8785 demonstrated only limited applicability as a reference material for C-14 analysis of carbonaceous aerosols. C-14 analysis of EC revealed a large deviation between the laboratories of 28-79% as a consequence of different separation techniques. This result indicates a need for further discussion on optimal methods of EC isolation for C-14 analysis and a second stage of this intercomparison.

Publiceringsår

2013

Språk

Engelska

Sidor

1496-1509

Publikation/Tidskrift/Serie

Radiocarbon

Volym

55

Issue

2-3

Dokumenttyp

Artikel i tidskrift

Förlag

Arizona Board of Regents (University of Arizona)

Ämne

  • Subatomic Physics

Status

Published

ISBN/ISSN/Övrigt

  • ISSN: 0033-8222