Webbläsaren som du använder stöds inte av denna webbplats. Alla versioner av Internet Explorer stöds inte längre, av oss eller Microsoft (läs mer här: * https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Var god och använd en modern webbläsare för att ta del av denna webbplats, som t.ex. nyaste versioner av Edge, Chrome, Firefox eller Safari osv.

Statistical methods for monitoring the relationship between the IFCC reference measurement procedure for hemoglobin A(1c) and the designated comparison methods in the United States, Japan, and Sweden

Författare

  • Andrea Geistanger
  • Sabine Arends
  • Christoph Berding
  • Tadao Hoshino
  • Jan-Olof Jeppsson
  • Randie Little
  • Carla Siebelder
  • Cas Weykamp

Summary, in English

BACKGROUND: The American Diabetes Association (ADA)/European Association for the Study of Diabetes (EASD)/International Diabetes Federation GDFAFCC Consensus Statement on the worldwide standardization of HbA(1c) states that"...[HbA(1c)] results are to be reported world-wide in IFCC units...and derived NGSP units...,using the IFCC-NGSP master equation." METHODS: We describe statistical methods to evaluate and monitor the relationships as expressed in master equations (MEs) between the IFCC Reference Measurement procedure (IFCC-RM) and designated comparison methods (DCMs) [US National Glycohemoglobin Standardization Program (NGSP), Japanese Diabetes Society/Japanese Society for Clinical Chemistry (JDS/JSCC), and Mono-S in Sweden]. We applied these statistics, including uncertainty calculations, to 12 studies in which networks of reference laboratories participated, operating the IFCC-RM and DCMs. RESULTS: For NGSP and Mono-S, slope, intercept, and derived percentage HbA(1c) at the therapeutic target show compliance with the respective MEs in all 12 studies. For JDS/JSCC, a slight deviation is seen in slope and derived percentage HbA(1c) in 2 of the 12 studies. Using the MEs, the uncertainty in an assigned value increases from 0.42 mmol/mol HbA(1c) (IFCC-RM) to 0.47 (NGSP), 0.49 (JDS/JSCC), and 0.51 (Mono-S). CONCLUSIONS: We describe sound statistical methods for the investigation of relations between networks of reference laboratories. Application of these statistical methods to the relationship between the JFCC-RM and DCMs in the US, Japan, and Sweden shows that they are suitable for the purpose, and the results support the applicability of the ADA/EASD/lDF/lFCC Consensus Statement on HbA1c measurement. (C) 2008 American Association for Clinical Chemistry.

Publiceringsår

2008

Språk

Engelska

Sidor

1379-1385

Publikation/Tidskrift/Serie

Clinical Chemistry

Volym

54

Issue

8

Dokumenttyp

Artikel i tidskrift

Förlag

American Association for Clinical Chemistry

Ämne

  • Biochemistry and Molecular Biology

Status

Published

Forskningsgrupp

  • Clinical Chemistry, Malmö

ISBN/ISSN/Övrigt

  • ISSN: 0009-9147