Webbläsaren som du använder stöds inte av denna webbplats. Alla versioner av Internet Explorer stöds inte längre, av oss eller Microsoft (läs mer här: * https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Var god och använd en modern webbläsare för att ta del av denna webbplats, som t.ex. nyaste versioner av Edge, Chrome, Firefox eller Safari osv.

Magnetic calculations of a superconducting undulator at the ESRF

Författare

  • Erik Wallén
  • J Chavanne
  • P Elleaume

Summary, in English

2D and 3D models of a superconducting undulator suitable for the ESRF storage ring have been developed. The models are based on the performance of superconducting NbTi wire available from the cabling industry. Iron is used in the poles to enhance the peak field. The 2D model shows that it is possible to obtain a peak field of 1.18 T, corresponding to a K-value of 1.65, for a period length of 15 mm, a magnetic gap of 6.5 mm, and a current density of 1050 A/mm(2) in the superconducting coils. 1050 A/mm(2) corresponds to 80% of the critical current density in the coils. A 3D model of the central parts of the undulator close to the storage ring shows that it is possible to obtain a negligible first and second field integral at the nominal current density of 1050 A/mm(2) and moderate field integrals at lower current densities. A full 3D model including the current leads and the path of the current carrying wires shows that an accurate arrangement of the current leads and path of the current carrying wires is essential but difficult to obtain. A precise design of the current leads and the path for the current carrying wire has not yet been found and this requires further empirical knowledge of the winding technique. The heat load to the cold mass of a 100 period superconducting undulator with a vertical accelerator vacuum aperture of 6.0 mm and a period length of 15 mm length has been estimated. The heat load is in the range 3.4-5.8 W, depending on the filling mode of the ESRF storage ring. The dominating heat load is the heating due to the resistive wall effect. Four local cooling machines, each with a cooling capacity of 1.5 W at about 4 K, would give enough cooling capacity for the foreseen filling modes of the ESRF storage ring.

Publiceringsår

2005

Språk

Engelska

Sidor

630-650

Publikation/Tidskrift/Serie

Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment

Volym

541

Issue

3

Dokumenttyp

Artikel i tidskrift

Förlag

Elsevier

Ämne

  • Accelerator Physics and Instrumentation

Nyckelord

  • superconducting undulator
  • insertion device
  • undulator
  • radiation
  • synchrotron

Status

Published

ISBN/ISSN/Övrigt

  • ISSN: 0167-5087