Webbläsaren som du använder stöds inte av denna webbplats. Alla versioner av Internet Explorer stöds inte längre, av oss eller Microsoft (läs mer här: * https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Var god och använd en modern webbläsare för att ta del av denna webbplats, som t.ex. nyaste versioner av Edge, Chrome, Firefox eller Safari osv.

Analysis of spatial variability in hyperspectral imagery of the uterine cervix in vivo

Författare

  • Michael J. deWeert
  • Jody Oyama
  • Elisabeth McLaughlin
  • Ellen Jacobson
  • Johan Håkansson
  • Gary S. Bignami
  • Ulf Gustafsson
  • Paul Troy
  • Violeta Poskiene
  • Kristina Kriukelyte
  • Reda Ziobakieni R,
  • Aurelija Vaitkuvieni A,
  • Sara Pålsson
  • Marcelo Soto Thompson
  • Unne Stenram
  • Stefan Andersson-Engels
  • Sune Svanberg
  • Katarina Svanberg

Summary, in English

The use of fluorescence and reflectance spectroscopy in the analysis of cervical histopathology is a growing field of research. The majority of this research is performed with point-like probes. Typically, clinicians select probe sites visually, collecting a handful of spectral samples. An exception to this methodology is the Hyperspectral Diagnostic Imaging (HSDI®) instrument developed by Science and Technology International. This non-invasive device collects contiguous hyperspectral images across the entire cervical portio. The high spatial and spectral resolution of the HSDI instruments make them uniquely well suited for addressing the issues of coupled spatial and spectral variability of tissues in vivo. Analysis of HSDI data indicates that tissue spectra vary from point to point, even within histopathologically homogeneous regions. This spectral variability exhibits both random and patterned components, implying that point monitoring may be susceptible to significant sources of noise and clutter inherent in the tissue. We have analyzed HSDI images from clinical CIN (cervical intraepithelial neoplasia) patients to quantify the spatial variability of fluorescence and reflectance spectra. This analysis shows the spatial structure of images to be fractal in nature, in both intensity and spectrum. These fractal tissue textures will limit the performance of any point-monitoring technology.

Publiceringsår

2003

Språk

Engelska

Sidor

67-76

Publikation/Tidskrift/Serie

Proceedings of SPIE

Volym

4959

Dokumenttyp

Artikel i tidskrift

Förlag

SPIE

Ämne

  • Cancer and Oncology

Nyckelord

  • Cervical
  • Cancer
  • CIN
  • Fractal
  • Tissue Classification
  • Fluorescence
  • Spectroscopy
  • HSDI
  • Medical Imaging
  • Histopathology

Aktiv

Published