Development of the combat sleeping bag system of the Latvian National Armed Forces
Författare
Summary, in English
Protection from the cold and thermal infrared surveillance during the low level metabolic heat rate of sleeping (40 W/m2) is the key aspect of the survivability of the soldier in combat and training operation to maintain task fulfilled. Three level CSBS were evaluated in conjunction with eleven combinations of the combat dress uniform system (CDU) of the LNAF Combat individual protection system (CIPS). There is no existing standard for the requirements of the combat sleeping bags.
The evaluation was done under the modified civil standard EN 13537:2002 “Requirements for sleeping bags” in the climatic chamber of the Lund University. LNAF had special needs of the location of the mannequin according to the operation using and possible location of the soldier inside sleeping bag, closing mode of the sleeping bag, as well as area of the sleeping bag contact points to the ground during the combat and training.
Parallel calculation method was used and the values were corrected for standard. CSBS providing protection comply with the requirements of NATO AECTP-230 “Climatic conditions” cold climate categories C0, C1, representing actual climatic condition of the Republic of Latvia, as well as ISAF operation region.
The following range of the quality was established during evaluation – lowest level Itot, parallel=0.824 m2K/W, Itot, serial=0.881 m2K/W, Itot, standard=0.758 m2K/W, comfort temperature +8.8 °C, limit temperature +4.4 °C, extreme temperature –9 °C; highest level Itot, parallel=1.612 m2K/W, Itot, serial=1.819 m2K/W, Itot, standard=1.383 m2K/W, Comfort temperature –10.5 °C, limit temperature –18.1 °C, extreme temperature –40.2 °C. Increasing number of layers doesn’t provide adequate increase of the thermal insulation, due to compressing of the layers and decreasing amount of the static air.
Physiological model for calculation of extreme temperature of the standard EN 13537:2002 “Requirements for the sleeping bags” utilizes 25 years old female with weight of 60 kg, height of 1.60 m, and body area of 1.62 m2. LNAF average soldier’s corresponding parameters are male, 24 years old, weight 81 kg, height 1.81 m and body area 2,0 m2. Difference between physiological model of the standard EN 13537:2002 and LNAF soldier should be evaluated during the field trial under the life weather condition.
The high level of the CSBS protection against thermal infrared surveillance was defined during the field evaluation. There is no any standard defines requirements of the thermal infrared protection level. Difference in ergonomic models and customizing of the thermal infrared protection evaluation making limitation of the logistics system in order to provide ability of making open tenders.
Avdelning/ar
Publiceringsår
2014
Språk
Engelska
Publikation/Tidskrift/Serie
6th European Conference on Protective Clothing
Fulltext
- Available as PDF - 172 kB
- Available as PDF - 317 kB
- Download statistics
Dokumenttyp
Konferensbidrag
Förlag
CENTEXBEL
Ämne
- Production Engineering, Human Work Science and Ergonomics
Conference name
6th European Conference on Protective Clothing and NOKOBETEF 11
Conference date
2014-05-14 - 2014-05-16
Conference place
Bruges, Belgium
Status
Published
Forskningsgrupp
- Thermal Environment Laboratory