Thermal properties on high fill factor electrical windings: Infiltrated vs non infiltarted

Författare

Summary, in English

This paper presents a comparison of the

thermal properties between infiltrated and non-infiltrated

copper windings. The focus is on thermal conductivity in the

radial direction on the winding. The samples have a fill factor

above 65 % due to the manufacturing method of the samples.

Samples are produced and measured with the transient plane

source technique and then compared to FEM simulations and

the Hashin and Shtrikman approximation. The results show a

considerable difference between a non-infiltrated and an

infiltrated winding, as well as a good agreement between

measurements, FEM simulations and the Hashin and

Shtrikman approximation

Publiceringsår

2014

Språk

Engelska

Sidor

2218-2223

Publikation/Tidskrift/Serie

2014 International Conference on Electrical Machines (ICEM)

Dokumenttyp

Konferensbidrag

Förlag

IEEE - Institute of Electrical and Electronics Engineers Inc.

Ämne

  • Materials Engineering

Nyckelord

  • Thermal analysis
  • Thermal conductivity
  • Coils
  • Winding
  • Fill factor
  • Infiltrated
  • Non-infiltrated

Conference name

International Conference on Electrical Machines (ICEM), 2014

Conference date

2014-09-02 - 2014-09-05

Conference place

Berlin, Germany

Status

Published

ISBN/ISSN/Övrigt

  • ISBN: 9781479943883