Webbläsaren som du använder stöds inte av denna webbplats. Alla versioner av Internet Explorer stöds inte längre, av oss eller Microsoft (läs mer här: * https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Var god och använd en modern webbläsare för att ta del av denna webbplats, som t.ex. nyaste versioner av Edge, Chrome, Firefox eller Safari osv.

Restrained shrinkage of massive masonry walls

Författare

Redaktör

  • Dirk Martens

Summary, in English

Restrained shrinkage of massive, one-storey, non-load bearing masonry walls with one-sided restraint has been simulated. A discontinuum model, including tensile and shear failure of mortar joints is employed to reproduce masonry behaviour in crack zones. Where cracking is not expected, masonry is modelled as an elastic continuum. The model is implemented in the commercial finite element programme ANSYS. The simu-lations show that cracking of walls is delayed if slip joints with low cohesion are applied at the wall foundation boundary or if weaker, lime rich mortars are employed instead of strong, cement rich mortars.

Publiceringsår

2004

Språk

Engelska

Sidor

449-458

Publikation/Tidskrift/Serie

[Host publication title missing]

Volym

2

Dokumenttyp

Konferensbidrag

Förlag

Eindhoven University of Technology

Ämne

  • Building Technologies

Nyckelord

  • Masonry
  • cracking
  • simulation
  • KstrMasonry
  • restrained shrinkage

Conference name

13th International Brick/Block Masonry Conference

Conference date

2004-07-04 - 2004-07-04

Status

Published

ISBN/ISSN/Övrigt

  • ISBN: 90-90-18294-2