Protection against cold in prehospital care: wet clothing removal or addition of a vapor barrier

Författare

  • Otto Henriksson
  • Peter J. Lundgren
  • Kalev Kuklane
  • Ingvar Holmér
  • Gordon G. Giesbrecht
  • Peter Naredi
  • Ulf Bjornstig

Summary, in English

Objective



The purpose of this study was to evaluate the effect of wet clothing removal or the addition of a vapor barrier in shivering subjects exposed to a cold environment with only limited insulation available.



Methods



Volunteer subjects (n = 8) wearing wet clothing were positioned on a spineboard in a climatic chamber (–18.5°C) and subjected to an initial 20 minutes of cooling followed by 30 minutes of 4 different insulation interventions in a crossover design: 1) 1 woolen blanket; 2) vapor barrier plus 1 woolen blanket; 3) wet clothing removal plus 1 woolen blanket; or 4) 2 woolen blankets. Metabolic rate, core body temperature, skin temperature, and heart rate were continuously monitored, and cold discomfort was evaluated at 5-minute intervals.



Results



Wet clothing removal or the addition of a vapor barrier significantly reduced metabolic rate (mean difference ± SE; 14 ± 4.7 W/m2) and increased skin temperature rewarming (1.0° ± 0.2°C). Increasing the insulation rendered a similar effect. There were, however, no significant differences in core body temperature or heart rate among any of the conditions. Cold discomfort (median; interquartile range) was significantly lower with the addition of a vapor barrier (4; 2–4.75) and with 2 woolen blankets (3.5; 1.5–4) compared with 1 woolen blanket alone (5; 3.25–6).



Conclusions



In protracted rescue scenarios in cold environments with only limited insulation available, wet clothing removal or the use of a vapor barrier is advocated to limit the need for shivering thermogenesis and improve the patient’s condition on admission to the emergency department.

Publiceringsår

2015

Språk

Engelska

Sidor

11-20

Publikation/Tidskrift/Serie

Wilderness & Environmental Medicine

Volym

26

Issue

1

Dokumenttyp

Artikel i tidskrift

Förlag

Elsevier

Ämne

  • Production Engineering, Human Work Science and Ergonomics

Nyckelord

  • hypothermia heat loss thermal insulation emergency medical services

Status

Published

Forskningsgrupp

  • Thermal Environment Laboratory

ISBN/ISSN/Övrigt

  • ISSN: 1080-6032