Range-resolved detection of potassium chloride using picosecond differential absorption light detection and ranging
Författare
Summary, in English
A laser diagnostic concept for measurement of potassium chloride (KCl) and potentially other alkali compounds in large-scale boilers and furnaces of limited optical access is presented. Single-ended, range-resolved, quantitative detection of KCl is achieved by differential absorption light detection and ranging (DIAL) based on picosecond laser pulses. Picosecond DIAL results have been compared experimentally with line-of-sight measurements using a commercial instrument, the in situ alkali chloride monitor (IACM), utilizing differential optical absorption spectroscopy. For centimeter-scale range resolution and a collection distance of 2.5 m, picosecond DIAL allowed for measurement of KCl concentrations around 130 ppm at 1200 K, in good agreement with values obtained by IACM. The DIAL data indicate a KCl detection limit of around 30 ppm for the present experimental conditions. In addition, a double-pulse DIAL setup has been developed and demonstrated for measurements under dynamic conditions with strong Mie scattering. The picosecond DIAL results are discussed and related to possible implementations of the method for measurements in industrial environments. (C) 2015 Optical Society of America
Avdelning/ar
Publiceringsår
2015
Språk
Engelska
Sidor
1058-1064
Publikation/Tidskrift/Serie
Applied Optics
Volym
54
Issue
5
Dokumenttyp
Artikel i tidskrift
Förlag
Optical Society of America
Ämne
- Atom and Molecular Physics and Optics
Status
Published
ISBN/ISSN/Övrigt
- ISSN: 2155-3165