Webbläsaren som du använder stöds inte av denna webbplats. Alla versioner av Internet Explorer stöds inte längre, av oss eller Microsoft (läs mer här: * https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Var god och använd en modern webbläsare för att ta del av denna webbplats, som t.ex. nyaste versioner av Edge, Chrome, Firefox eller Safari osv.

Energy-efficient flat-tube heat exchangers for indirectly cooled display cabinets

Författare

Summary, in English

Different designs of flat-tube heat exchangers with plain fins have been evaluated theoretically in a parameter study in order to evaluate their performance potential in indirectly cooled display cabinets. Two different types of flat-tube heat exchangers were considered; one with serpentine fins and one with continuous plate fins. Both flat-tube heat exchanger types were adapted to the laminar flow regime on the liquid as well as on the air side. The performance of the two heat exchanger types had previously been verified experimentally under dehumidifying conditions. The results from this parameter study show that considerable savings in the required electric drive power to compressors, pumps and fans can be obtained in comparison with the traditional cooling coil. The savings may be up to 15%. In addition, the required temperature difference for the flat-tube heat exchangers is so small that frost-free operation is possible, which would result in even larger savings. (C) 2009 Elsevier Ltd and IIR. All rights reserved.

Avdelning/ar

Publiceringsår

2009

Språk

Engelska

Sidor

1460-1471

Publikation/Tidskrift/Serie

International Journal of Refrigeration

Volym

32

Issue

6

Dokumenttyp

Artikel i tidskrift

Förlag

Elsevier

Ämne

  • Energy Engineering

Nyckelord

  • Energy efficiency
  • Calculation
  • Geometry
  • Finned tube
  • Tube
  • Heat exchanger
  • Display cabinet

Status

Published

ISBN/ISSN/Övrigt

  • ISSN: 0140-7007