Comparison of heat transfer from baby and adult manikins

Författare

  • Kalev Kuklane
  • Ingvar Holmér
  • Yutaka Tochihara
  • Takako Fukazawa
  • Gung Lee
  • Takashi Nonaka
  • Takashi Noguchi

Redaktör

  • Victor Candas

Summary, in English

Data from 3 whole body manikins, 2 babies and an adult, were used in the study. All the manikins used the same computer program and similar measuring and control units. No special measurements were made for baby and adult manikin comparison, but available data from earlier measurements was used. The conditions involved air layer insulation measurements (AL), laying on back on an insulating surface (OB), and laying on back on insulating surface and covered with a sheet (OBS, baby manikins only).

AL insulation/heat transfer coefficients (HTC) for all manikins were very similar. OB condition adult manikin differed from others. That was related to flexible joints allowing arms and legs to be in contact with insulating surface while baby manikins still had their arms and legs in air. Baby manikins performed similarly in OBS test.

No significant differences in heat transfer from manikins depending on body size were observed. On the other hand, body posture related to rigid/flexible joints, e.g. laying on back condition, and even small differences in air velocity could have an effect. Care should be taken when interpreting results related to measurement values from separate zones or relatively small zone groups because of large errors. In this study only simple, undressed conditions were tested. Therefore, a question would be at which size and insulation level the differences occur and/or become critical. A study with specially manufactured well-fitting clothes on manikins of different sizes could answer the question.

Publiceringsår

2003

Språk

Engelska

Publikation/Tidskrift/Serie

5th International Meeting on Thermal Manikin and Modelling (5I3M)

Dokumenttyp

Konferensbidrag

Förlag

CEPA, Strasbourg, France

Ämne

  • Production Engineering, Human Work Science and Ergonomics

Nyckelord

  • body size
  • thermal insulation
  • baby manikin

Conference name

5th International Meeting on Thermal Manikin and Modelling (5I3M)

Conference date

2003-09-29 - 2003-09-30

Conference place

Strasbourg, France

Status

Published

Forskningsgrupp

  • Thermal Environment Laboratory