A simplified non-linear model of a drum boiler - turbine unit
Författare
Summary, in English
In the analysis of power systems it is highly desirable to have models of the different power generators. In this paper we present, a model for a drum boiler whose purpose is to describe the gross behaviour of the boiler. The major control variables are fuel flow and control valve setting. The output variables are drum pressure and active output power. The model is verified by experiments on a 160 Mw boiler.
Avdelning/ar
Publiceringsår
1972
Språk
Engelska
Sidor
145-169
Publikation/Tidskrift/Serie
International Journal of Control
Volym
16
Issue
1
Fulltext
Dokumenttyp
Artikel i tidskrift
Förlag
Taylor & Francis
Ämne
- Control Engineering
Status
Published
ISBN/ISSN/Övrigt