Association between Atrial Fibrillatory Rate and Heart Rate Variability in Patients with Atrial Fibrillation and Congestive Heart Failure

Författare

Summary, in English

Background Even if atrial fibrillatory rate (AFR) has been related to clinical outcome in patients with atrial fibrillation (AF), its relation with ventricular response has not been deeply studied. The aim of this study was to investigate the relation between AFR and RR series variability in patients with AF. Methods Twenty-minute electrocardiograms in orthogonal leads were processed to extract AFR, using spatiotemporal QRST cancellation and time frequency analysis, and RR series in 127 patients (age 69 +/- 11 years) with congestive heart failure (NYHA IIIII) enrolled in the MUSIC study (MUerte Subita en Insufficiencia Cardiaca). Heart rate variability and irregularity were assessed by time domain parameters and entropy-based indices, respectively and their correlation with AFR investigated. Results Variability measures seem not to be related to AFR, while irregularity measures do. A significant correlation between AFR and variability parameters of heart rate variability during AF was found only in patients not treated with antiarrhythmics drugs (correlation = 0.56 P < 0.05 for pNN50), while this correlation was lost in patients taking rate- or rhythm-control drugs. A significant positive correlation between AFR and indices of RR irregularity was found, showing that a higher AFR is related to a less organized RR series (correlation = 0.33 P < 0.05 for regularity index for all patients, correlation increased in subgroups of patients treated with the same drug). Conclusions These results suggest that a higher AFR is associated with a higher degree of irregularity of ventricular response that is observed regardless of the use of rate-controlling drugs. Ann Noninvasive Electrocardiol 2013;18(1):41-50

Publiceringsår

2013

Språk

Engelska

Sidor

41-50

Publikation/Tidskrift/Serie

Annals of Noninvasive Electrocardiology

Volym

18

Issue

1

Dokumenttyp

Artikel i tidskrift

Förlag

Wiley-Blackwell

Ämne

  • Cardiac and Cardiovascular Systems

Nyckelord

  • atrial fibrillation
  • frequency
  • time domain parameters
  • approximate
  • entropy
  • regularity
  • congestive heart failure

Status

Published

ISBN/ISSN/Övrigt

  • ISSN: 1082-720X