Webbläsaren som du använder stöds inte av denna webbplats. Alla versioner av Internet Explorer stöds inte längre, av oss eller Microsoft (läs mer här: * https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Var god och använd en modern webbläsare för att ta del av denna webbplats, som t.ex. nyaste versioner av Edge, Chrome, Firefox eller Safari osv.

Generation of hexahydrophthalic anhydride atmospheres in a controlled human-use test chamber

Författare

  • Bo A Jönsson
  • Hans Welinder
  • Gunnar Skarping

Summary, in English

A method for generating controlled atmospheres of hexahydrophthalic anhydride (HHPA) in an 8 m3 exposure chamber was developed. The permeation principle was used for gaseous HHPA generation. HHPA concentration was monitored by sampling on XAD-2 tubes and by a Fourier-transform infrared (FTIR) spectrometer using the partial least-square quantitative method. The repeatability of the FTIR was 5%, the reproducibility 12%, and the limit of detection 10 micrograms/m3. A bubbler method determined the sum of HHPA and HHP acid by using gas chromatography/mass spectrometry detection after derivatization with methanol/boron trifluoride. The precision of the work-up procedure was 3% and the recovery was 94% at 300 ng sampled amount of HHPA. The limit of detection was 10 ng HHPA. The variation in the permeation rate was 3% over 3 days. Different concentrations in the exposure chamber were generated by changing the temperature of the permeation tubes. The generated HHPA concentration range, at human exposure, was 3-90 micrograms/m3. The concentration at one temperature was reproducible even after major changes in the temperature. The coefficient of variation (CV) of six samples from different places in the breathing zone was 3%. The variation in the concentration, during an 8-hour human exposure at 10 micrograms/m3, was 3%. Time-weighted averages (8 hour) for human exposures of 10 micrograms/m3 (CV = 15%; n = 6); 37 micrograms/m3 (CV = 5%; n = 5); and 81 micrograms/m3 (CV = 6%; n = 9) were obtained at intended concentrations of 10 micrograms/m3, 40 micrograms/m3, and 80 micrograms/m3. The loss of HHPA in the exposure chamber was 54% (CV = 17%).(ABSTRACT TRUNCATED AT 250 WORDS)

Publiceringsår

1994

Språk

Engelska

Sidor

330-338

Publikation/Tidskrift/Serie

American Industrial Hygiene Association Journal

Volym

55

Issue

4

Dokumenttyp

Artikel i tidskrift

Förlag

Taylor & Francis

Ämne

  • Environmental Health and Occupational Health

Status

Published

ISBN/ISSN/Övrigt

  • ISSN: 1542-8117